QA Technology Company, Inc. logo
Competitor Cross Reference icon View Cart
Competitor Cross Reference icon View Cart

ICO Test Data Summary

Below is a summary of the various independent testing done on our integraMate ICO Series. Conctact QA for more information

Test Standard Description ICOA5 ICO60
EIA 364-23B
LLCR <2.0 mΩ <4.0 mΩ
EIA 364-9C Durability / 100,000 cycles <1.0 mΩ change <2.0 mΩ change
EIA 364-37B Engagement & Separation Forces
1.0 oz gauge pin/4.0 oz mating pin/Bilaterally Equal 1.0 oz gauge pin/2.0 oz mating pin/Bilaterally Equal
EIA 364-31B Cyclic Humidity 240 hours / 10 cycles / 98% RH / 30k cycles preconditioning  / <2.0 mΩ change  
EIA 364-70A Ratings 12 Amps with 30°C rise (3 circuits energized) 4 Amps with 30°C rise (7 circuits energized
EIA 364-32C Thermal Shock -25°C to 105°C, 5 cycles <2.0 mΩ change  
EIA 364-36A Gas Tight 1 hour exposure / <2.0 mΩ change  
EIA 364-17B Temperature Life 250 hours @ 85°C / <2.0 mΩ change  
EIA 364-27B Mechanical Shock 50Gs / <2.0 mΩ change / No discontinuity >1 microsecond  
EIA 364-28D Random Vibration 19.64Grms / <2.0 mΩ change / No discontinuity >1 micorsecond  
EIA 364-32C Thermal Cycling 0°C to 100°C, 250 cycles / <2.0 milliohm change