Below is a summary of the various independent testing done on our integraMate ICO Series. Conctact QA for more information
| Test Standard | Description | ICOA5 | ICO60 | 
| EIA 364-23B | LLCR | <2.0 mΩ | <4.0 mΩ | 
| EIA 364-9C | Durability / 100,000 cycles | <1.0 mΩ change | <2.0 mΩ change | 
| EIA 364-37B | Engagement & Separation Forces | 1.0 oz gauge pin/4.0 oz mating pin/Bilaterally Equal | 1.0 oz gauge pin/2.0 oz mating pin/Bilaterally Equal | 
| EIA 364-31B | Cyclic Humidity | 240 hours / 10 cycles / 98% RH / 30k cycles preconditioning / <2.0 mΩ change | |
| EIA 364-70A | Ratings | 12 Amps with 30°C rise (3 circuits energized) | 4 Amps with 30°C rise (7 circuits energized | 
| EIA 364-32C | Thermal Shock | -25°C to 105°C, 5 cycles <2.0 mΩ change | |
| EIA 364-36A | Gas Tight | 1 hour exposure / <2.0 mΩ change | |
| EIA 364-17B | Temperature Life | 250 hours @ 85°C / <2.0 mΩ change | |
| EIA 364-27B | Mechanical Shock | 50Gs / <2.0 mΩ change / No discontinuity >1 microsecond | |
| EIA 364-28D | Random Vibration | 19.64Grms / <2.0 mΩ change / No discontinuity >1 micorsecond | |
| EIA 364-32C | Thermal Cycling | 0°C to 100°C, 250 cycles / <2.0 milliohm change |